MA8 Aligner

The MA8 is very new tool. Because the tool is very new, user interface is easy and straight forward. 

Initialization

Replace mask holder

Install photomask

The tool will ask you to remove wafer from chuck and close the lid. Then, the tool will run self calibration. This is the goodness. For the old aligners, like EVG620 or MA6, we don't really know the UV light intensity for each exposure. Xiaoyu experienced the EVG620's story. EVG620 is using a UV light bulb as a source. When Xiaoyu needs to use the tool, Xiaoyu has to measure the UV intensity by himself. And then he calculate the exposure time based the time-varying UV intensity. That was painful.  

Load wafer

The wafer should be aligned by both small nails and holes. The small holes are for vacuum mode. 

Alignment

Exposure

Unload wafer

Unload mask